6 Commissioning
6.5 Establishing an online connection with the »Engineer«
42
Lenze · E84AYCET communication module (EtherCAT) · Communication Manual · DMS 5.0 EN · 05/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
How to configure an online connection to a field device which is connected to the Lenze
Controller via EtherCAT:
1. Go to the Communication path dialog box and the Bus connection list field, and select the
entry "Gateway Controller -> EtherCAT" there.
2. Click Search/Enter....
The Gateway Controller -> Set up EtherCAT bus dialog box is shown:
3. Enter the IP address of the Controller.
By clicking the Ping button, you can carry out a simple test which verifies whether a device
can actually be reached via the IP address set
4. Click OK.
•The Enter IP address dialog box is closed.
•In the Communication path dialog box in the Device access path column, the
corresponding device access path is shown
(e.g. "IPC:172_31_207_254.ECAT.ecat1.dev1001.").