9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Parameterisable function blocks
184 L EDS94TA11010xxxx EN 1.2 - 03/2010
3.21.6 DetectMultiError
3.21.7 DetectSingleError
is ans instance of Function
L_TbCompare Recognition of multiple errors
Parameter Possible settings Information
C04087 Comparison operation
0 dnIn1 = dnIn2
1 dnIn1 > dnIn2 Lenze setting
2 dnIn1 < dnIn2
3 |dnIn1| = |dnIn2|
4 |dnIn1| > |dnIn2|
5 |dnIn1| < |dnIn2|
is ans instance of Function
L_TbCompare Recognition of single errors
Parameter Possible settings Information
C04086 Comparison operation
0 dnIn1 = dnIn2 Lenze setting
1 dnIn1 > dnIn2
2 dnIn1 < dnIn2
3 |dnIn1| = |dnIn2|
4 |dnIn1| > |dnIn2|
5 |dnIn1| < |dnIn2|