Lenze E94AxHE Technology Application CiA402 Device profi Instrukcja Użytkownika Strona 96

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 232
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 95
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Homing mode
96 L EDS94TA11010xxxx EN 1.2 - 03/2010
Case 3: Axis already stands on reference switch:
1. Movement in positive direction with profile data set 2.
2. Negative edge of the reference switch activates touch probe detection.
3. The following positive edge of the encoder zero pulse/touch probe sensor sets the
reference (0x607C
).
4. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").
CiA402 Homing method 11
Processes:
Case 1: Axis does not activate reference switch on the way to the limit switch:
1. Movement in negative direction with profile data set 1.
2. Reversing to negative travel range limit switch.
3. Positive edge of the reference switch activates profile data set 2.
4. Negative edge of the reference switch activates touch probe detection.
5. The following positive edge of the encoder zero pulse/touch probe sensor sets the
reference (0x607C
).
6. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").
Touch probe/zero pulse
 Reference switch
 Negative travel range limit switch
3
1
2
0
1
2
Przeglądanie stron 95
1 2 ... 91 92 93 94 95 96 97 98 99 100 101 ... 231 232

Komentarze do niniejszej Instrukcji

Brak uwag