9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Homing mode
86 L EDS94TA11010xxxx EN 1.2 - 03/2010
CiA402 Homing method 02
Process:
1. Movement in positive direction with profile data set 1.
2. Reversing to positive travel range limit switch and change to profile data set 2.
3. Negative edge of the travel range limit switch activates touch probe detection.
4. The following positive edge of the encoder zero pulse/touch probe sensor sets the
reference (0x607C
).
5. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").
Touch probe/zero pulse
Positive travel range limit switch
1
0
1