9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Device control
44 L EDS94TA11010xxxx EN 1.2 - 03/2010
0x605A - Quick stop option code
0x605B - Shutdown option code
0x605C - Disable operation option code
0x605D - Halt option code
0x605E - Fault reaction option code
Index | Name:
0x605A | Quick stop option code
Data type: INTEGER_16
Code: C03534
Response to request for quick stop.
2 = activate quick stop. quick stop
Setting range (min. value | unit | max. value) Lenze setting
222
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x605B | Shutdown option code
Data type: INTEGER_16
Code: C03532
Response to request for drive shutdown.
0 = set controller inhibit.
Setting range
(min. value | unit | max. value) Lenze setting
000
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x605C | Disable operation option code
Data type: INTEGER_16
Code: C03533
Response to deselection of the operating mode.
0 = set controller inhibit.
Setting range
(min. value | unit | max. value) Lenze setting
000
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x605D | Halt option code
Data type: INTEGER_16
Code: C03535
Response to halt command.
2 = activate quick stop. quick stop
Setting range (min. value | unit | max. value) Lenze setting
222
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x605E | Fault reaction option code
Data type: INTEGER_16
Code: C03536
Response to drive fault.
2 = activate quick stop. quick stop
Setting range (min. value | unit | max. value) Lenze setting
222
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX