EDS94TA11010xxxx EN 1.2 - 03/2010 L 29
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Drive initialisation
SDO write request 0x1A00/1 0x60410010 Map the 0x6041 object (statusword) to PDO1-Tx.
SDO write request 0x1A00/2 0x60640020 Map the 0x6064
object (position actual value) to
PDO1-Rx.
SDO write request 0x1A00/0 2 PDO1-Tx contains 2 objects; activate mapping.
SDO write request 0x1C12/1 Selection of the PDO-Rx source
SDO write request 0x1C13/1 Selection of the PDO-Tx source
Initialisation of device profile objects
SDO write request 0x60C2/1 2 Set time base for interpolation of the position
setpoint.
Time base = 2 x 10
-3
[s] = 2 [ms]
SDO write request 0x60C2/2 0xFD (-3)
SDO write request 0x6092/1 0x10000 Set feed constant for position values in [increments].
One encoder revolution corresponds to 0x10000,
since the feed is usually already converted into
increments in the master control.
SDO write request 0x6060 7 Select the "Interpolated position mode" operation
mode.
Initialisation of manufacturer-specific objects
SDO write request 0x55A4 0x10000 Configure touch probe for the "homing mode"
operation mode in C02651.
Touch probe is triggered by motor encoder zero
pulse.
SDO write request 0x55AF 2 Select "2" for "Homing mode" operating mode in
C02640.
Process:
1.Movement in positive direction with profile data
set 1.
2.Reversing to positive travel range limit switch.
3.Positive edge of the reference switch activates
profile data set 2 for the further reference search.
4.Negative edge of the reference switch enables
home position detection.
5.The following positive edge of the encoder zero
pulse/touch probe sensor sets the reference
(0x607C
).
6.Absolute positioning to target position (C02643)
with profile data set 2
(if 0x60FB/7
= "0").
SDO write request 0x5B9F 4 Write request on the code C01120 (sync source) for
axis synchronisation.
Value "4" = module in MXI1
Change of the communication status
NMT - - Switch drive to the OPERATIONAL communication
status.
Cyclic process data exchange
PDO1-Rx to the drive - - Transmit the process data to the drive according to
PDO mapping.
SYNC - - Process data synchronisation
PDO1-Tx from the drive - - Receive process data from the drive according to PDO
mapping.