Lenze · Controller-based Automation · EtherCAT® Communication Manual · DMS 6.4 EN · 04/2014 · TD17 185
12 Diagnostics
12.6 System error messages
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x98110037 ETC_E_EVAL_VIOLATION The number of slaves indicated in the XML file is too large for the evaluation
version of the master.
Internal error. Please contact Lenze.
0x98110038 ETC_E_EVAL_EXPIRED The evaluation time has expired. The fieldbus is stopped.
Internal error. Please contact Lenze.
0x98110040 ETC_E_SDO_ABORTCODE_TOGGLE The status of the toggle bit has not changed.
Abort code 0x05030000
0x98110041 ETC_E_SDO_ABORTCODE_TIMEOUT SDO protocol time-out
Abort code 0x05040000
0x98110042 ETC_E_SDO_ABORTCODE_CCS_SCS Invalid or unknown specification symbol for the client/server command
Abort code 0x05040001
0x98110043 ETC_E_SDO_ABORTCODE_BLK_SIZE Invalid block size (only in "Block mode")
Abort code 0x05040002
0x98110044 ETC_E_SDO_ABORTCODE_SEQNO Invalid sequence number (only in "Block mode")
Abort code 0x05040003
0x98110045 ETC_E_SDO_ABORTCODE_CRC CRC error (only in "Block mode")
Abort code 0x05040004
0x98110046 ETC_E_SDO_ABORTCODE_MEMORY Not enough space in the main memory
Abort code 0x05040005
0x98110047 ETC_E_SDO_ABORTCODE_ACCESS Access to object not supported
Abort code 0x06010000
0x98110048 ETC_E_SDO_ABORTCODE_WRITEONLY Read access to a write-protected object
Abort code 0x06010001
0x98110049 ETC_E_SDO_ABORTCODE_READONLY Write access to a write-protected object
Abort code 0x06010002
0x9811004A ETC_E_SDO_ABORTCODE_INDEX An object does not exist in the object directory
Abort code 0x06020000
0x9811004B ETC_E_SDO_ABORTCODE_PDO_MAP An object cannot be mapped into the PDO
Abort code 0x06040041
0x9811004C ETC_E_SDO_ABORTCODE_PDO_LEN The number and/or length of the objects mapped would exceed the PDO length
Abort code 0x06040042
0x9811004D ETC_E_SDO_ABORTCODE_P_INCOMP General parameter incompatibility
Abort code 0x06040043
0x9811004E ETC_E_SDO_ABORTCODE_I_INCOMP General internal device incompatibility
Abort code 0x06040047
0x9811004F ETC_E_SDO_ABORTCODE_HARDWARE Access has failed due to a fault in the hardware
Abort code 0x06060000
0x98110050 ETC_E_SDO_ABORTCODE_DATA_SIZE The data type or the parameter length does not correspond
Abort code 0x06070010
0x98110051 ETC_E_SDO_ABORTCODE_DATA_SIZE1 Incorrect data type (The parameter length is too large)
Abort code 0x06070012
0x98110052 ETC_E_SDO_ABORTCODE_DATA_SIZE2 Wrong data type (parameter length is too small).
Abort code 0x06070013
0x98110053 ETC_E_SDO_ABORTCODE_OFFSET A subindex is not available
Abort code 0x06090011
0x98110054 ETC_E_SDO_ABORTCODE_DATA_RANGE The value range for parameters is too great (only for write access)
Abort code 0x06090030
0x98110055 ETC_E_SDO_ABORTCODE_DATA_RANGE1 The parameter value is too high
Abort code 0x06090031
0x98110056 ETC_E_SDO_ABORTCODE_DATA_RANGE2 The parameter value is too low
Abort code 0x06090032
0x98110057 ETC_E_SDO_ABORTCODE_MINMAX The maximum value is lower than the minimum value
Abort code 0x06090036
0x98110058 ETC_E_SDO_ABORTCODE_GENERAL General error
Abort code 0x08000000
0x98110059 ETC_E_SDO_ABORTCODE_TRANSFER Data cannot be transferred/saved to the application.
Abort code 0x08000020
0x9811005A ETC_E_SDO_ABORTCODE_TRANSFER1 Data cannot be transferred/saved to the application because of local control.
Abort code 0x08000021
0x9811005B ETC_E_SDO_ABORTCODE_TRANSFER2 Due to the current device state, data cannot be transferred to the application or
stored in the application
Abort code 0x08000022