Lenze · ApplicationTemplate · 1.3 EN - 04/2013 13
Requirements
System requirements
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3 Requirements
3.1 System requirements
3.2 Establishing communication with the controller
• Connect the Engineering PC with the controller via a network cable. The »PLC Designer«
accesses the controller via Ethernet.
• Make the IP settings with the »PLC Designer«.
How to check the communication settings:
1. Double-click the desired controller in the Devices view.
2. Make the desired settings on the Communication settings tab.
•Click the Add gateway button to insert a gateway.
Engineering PC Controller
Hardware PC/notebook PLC (Logic) from firmware V3.3
Operating system Windows XP Windows CE
Required Lenze software »PLC Designer« from V3.3
•Contains the
ApplicationTemplate
• Contains the Lenze library
"L_EATP_ApplicationTemplate.co
mpiled-library"
Runtime software
•Logic
• Motion (this requires updating the
project information: "Update
devices")
Further requirements - Depending on the application case:
• CAN or EtherCAT bus system
• CAN or EtherCAT node