Lenze · ApplicationTemplate · 1.3 EN - 04/2013 87
Architecture: The ApplicationTemplate in detail
Default coupling
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
The method call has no impact on the connection of the ACD structure of the respective
machine module.
The master of the state machine can read out a decoupled module via the corresponding
baseChannelGetActualState methods.
Accessing the state machine - the methods of the BaseChannel
( 131)
The master of the respective state machine can read out the status of a decoupled module (via
the corresponding methods). The use of this mechanism is advisable if the module is provided
with at least one
higher-level master module.
Error response - response for the occurrence of an error
•The DisableDefaultCouplingSlave method decouples the slave module from the state machine
of the master module; example: decoupling M1.2.2 from M1.2.
•The Quick stop error status of M1.2 has no
impact on M1 and M1.1 (the M1.2 module is
decoupled from M1).
The state machine of the master module M1 no longer has an impact on the module M1.2
(due to the decoupling).
Error acknowledgement by the M1 master module no longer has an impact on M1.2 and its
slave modules.
[9-19] Sample program: Deactivating "DefaultCouplingSlave"
"DefaultCouplingSlave" methods - overview
: Error response to "Fault" status of M1.2.2 by
SMDisableDefaultCouplingSlave(xValue := TRUE);
Identifier/function Transfer value/data type Description
baseChannelGetDefaultCouplingSla
veDisabled
• Queries the status of the
DisableDefaultCouplingSlave
method of the respective module.
MM_Address
L_EATP_MM_Address
Address of the module the current
state of which is to be queried.
The value "0" and the
L_EATP_CONST.OWNID constant
address the module's intrinsic ID.
Return value/data type
BOOL
TRUE: Deactivate the standard
coupling of the master.
FALSE: Activate the standard
coupling of the master.
SMDisableDefaultCouplingSlave
• Activates/deactivates the
standard coupling of the slave.
xValue
BOOL
TRUE: Deactivate the standard
coupling of the slave
FALSE: Activate the standard
coupling of the slave