2.15 SYSTEM_FLAGS (system flags, node number 151)
2−87
L
9300 Servo PLC EN 5.0
SYSTEM_bTogCycleTask
This system flag toggles with the cyclic task:
1. cycle: FALSE
2. cycle: TRUE
3. cycle: FALSE
4. cycle: TRUE
etc.
SYSTEM_nTaskInterval
This system flag indicates the interval of the running task with a resolution of 0.25 ms.
If, for instance, a 10−ms task is processed, the system flag indicates "40"
(40 x 0.25 ms = 10 ms).
If a task different from an interval task is processed, the system flag indicates "0".
SYSTEM_nTaskID
This system flag indicates the task ID of the running task.
SYSTEM_b1LoopCyclicTask/SYSTEM_b1Loop Task X
These system flags are TRUE only once during the first cycle of a task.
After the first cycle, the flags will be set to FALSE.
The only way to reset the status to TRUE is to reset the program in the PLC.
2.15.2 Outputs SYSTEM_FLAGS
Variable Data type Address Notes
SYSTEM_bPLCResetAndRun Bool %QX151.0.0 This system flag carries out a reset with an immediate restart of the Drive PLC:
After the reset, the flag is deleted and the restart carried out.