9300 Servo PLC
System blocks
2.5 ANALOG1_IO (node number 11)
2−19
L
9300 Servo PLC EN 5.0
Terminal assignment
Set via C0034 whether the input is to be used for a master voltage or a master current.
Set jumper bar X3 according to setting in C0034:
Stop!
Do not plug the jumper on 3−4! The PLC cannot be initialised in this case.
Terminal Use Jumper X3 Measuring range
X6/1, 2
Differential input for
master voltage
6
4
2
5
3
1
C0034 = 0
Level:
Resolution:
Scaling:
−10 V ... +10 V
5 mV (11 bits + sign)
10 V 16384 100 %
Differential input for
master current
6
4
2
5
3
1
C0034 = 1
Level:
Resolution:
Scaling:
+4 mA ... +20 mA
20 A (10 bits without sign)
+4 mA 0 0 %
+20 mA +16384 +100 %
C0034 = 2
Level:
Resolution:
Scaling:
−20 mA ... +20 mA
20 A (10 bits + sign)
20 mA 16384 100 %
2.5.2 Outputs_ANALOG1 (analog output)
The output can be used as a monitor output. Internal analog signals can be output as voltage signals
via terminal X6/62 and used, for instance, as display values or setpoints for slave drives.
Outputs_ANALOG1
AOUT1_nOut_a
C0434
X6
62
Fig. 2−10 Outputs_ANALOG1
System variables
Variable Data type Signal type Address Display
code
Display
format
Note
AOUT1_nOut_a Integer Analog %QW11.0 C0434 dec [%] Analog output 1
Terminal assignment
Terminal Use Measuring range
X6/62 Analog output 1 (monitor 1) Level:
Resolution:
Scaling:
−10 V ... +10 V (max. 2 mA)
20 mV (9 bits + sign)
10 V 16384 100 %
X6/7 Internal ground, GND