9300 Servo PLC
Appendix
3.6 Code table
3−23
L
9300 Servo PLC EN 5.0
Code InfoPossible settingsLCDCode Info
SelectionLenze
LCD
C0061 Heatsink temp
g
Heatsink temperature
0 {1 °C} 100
C0063 Mot temp
g
Motor temperature
0 {1 °C} 200
C0064 Utilization
g
Controller load I x t during the last 180 seconds
C0064 >100 % trips OC5.
TRIP−RESET is only possible if C0064 < 95 %.
0 {1 %} 150
C0066 Motor load
g
I
2
× t−utilisation of the motor
0 {1 %} 250
C0067 Act trip
g
Current TRIP
("0" is displayed for FAIL−QSP, warning and message.)
C0070 Vp speed CTRL Proportional gain of speed controller (V
pn
)
Dependent on C0086
If C0086 is changed, the value is reset to the assigned
Lenze setting.
0.0 {0.5} 255.0
C0071 Tn speed CTRL Reset time of speed controller (T
nn
)
Dependent on C0086
If C0086 is changed, the value is reset to the assigned
Lenze setting.
1.0 {0.5 ms} 600.0
>512 ms = switched off
C0072 Td speed CTRL 0.0 Derivative gain of speed controller (T
dn
)
0.0 {0.1 ms} 32.0
C0075 Vp curr CTRL Proportional gain of current controller (V
pi
)
Dependent on C0086
If C0086 is changed, the value is reset to the assigned
Lenze setting.
0.00 {0.01} 15.99
C0076 Tn curr CTRL Reset time of current controller (T
ni
)
Dependent on C0086
If C0086 is changed, the value is reset to the assigned
Lenze setting.
0.5 {0.1 ms} 2000.0
2000 ms = switched off
C0077 Vp field CTRL 0.25 Proportional gain of field controller (V
pF
)
0.00 {0.01} 15.99
C0078 Tn field CTRL 15.0 Reset time of field controller (T
nF
)
1.0 {0.5 ms} 8000.0
8000 ms = switched off
[C0081] Mot power Rated motor power according to nameplate
Dependent on C0086
If C0086 is changed, the value is reset to the assigned
Lenze setting.
Change sets C0086 = 0
0.01 {0.01 kW} 500.00
[C0084] Mot Rs Stator resistance of the motor
Dependent on C0086
If C0086 is changed, the value is reset to the assigned
Lenze setting.
Change sets C0086 = 0.
0.00 {0.01 } 100.00