3.6 Code table
9300 Servo PLC
Appendix
3−28
L
9300 Servo PLC EN 5.0
Code InfoPossible settingsLCDCode Info
SelectionLenze
LCD
[C0089] Mot frequency Rated motor frequency
Dependent on C0086
If C0086 is changed, the value is reset to the assigned
Lenze setting.
Change sets C0086 = 0.
10 {1 Hz} 1000
[C0090] Mot voltage Rated motor voltage
Dependent on C0086
If C0086 is changed, the value is reset to the assigned
Lenze setting.
Change sets C0086 = 0.
50 {1 V} 500
[C0091] Mot cos phi Motor cos
Dependent on C0086
If C0086 is changed, the value is reset to the assigned
Lenze setting.
Change sets C0086 = 0.
0.50 {0.01} 1.00
C0093 DRIVE ident
g
Controller identification
0 Def. power stage
1 No power stage
93xx 93xx
C0094 Password 0 Keypad password protection
Parameter password protection for the keypad.
When the password is activated, only user−menu codes
can be accessed.
For extended password protection, please see C0096.
0 {1} 9999
0 = No password protection
[C0095] Rotor pos adj 0 Rotor position adjustment of a synchronous motor
C0058 displays the zero phase of the rotor
C0095 = 1 starts position adjustment
0 Not active
1 Active
C0096 AIF/CAN prot. AIF/CAN password protection
Extended password protection for bus systems when
password is activated (C0094).
All codes in the user menu can be accessed.
0 No password protection
1 Read protection
2 Write protection
3 Read/write protection
1 0 AIF password protection
2 0 CAN password protection
C0098 Zero pos offs 0 Setting the reference position of the feedback system
For position feedback (integrator output
MCTRL_dnPos_p of the motor control)
Only possible when the controller is inhibited.
Caution: This code returns an invalid value when it is
read.
−2147483647 {1 inc} 2147483647
C0099 S/W version
g
Software version of operating system
C0105 QSP Tif 0.000 Deceleration time for quick stop (QSP)
Referred to speed change n
max
(C0011) ... 0
0.000 {0.001 s} 999.900