Lenze PLC Designer PLC Designer (R2-x) Instrukcja Użytkownika Strona 30

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 844
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 29
L-force | PLC Designer
Lenze specifications
28 DMS 3.2 EN 02/2011 TD29
Error messages from the function block
Error number Meaning
507 Incorrect format specification during a write access
531 Incorrect format specification during the assignment
532 Code contains float/double parameters (e. g. supply voltage C00205 or
voltage of rechargeable battery C00207); this format is not supported by
the POU.
further Internal software error; please address the Lenze service.
2.2.2 The function LLS_AddLog - generate a logbook
Function library: PlcLoggingAccess.lib
This function renders it possible to make an entry in the logbook of the industrial PC.
The function supplies a return value TRUE if the entry was carried out.
Inputs
Identifier/data type Information/possible settings
eSeverity
LLS_TSeverity
Logging Severity - risk of the error
LLS_FatalError
LLS_Error, LLS_Warning
LLS_Information
The Enum parameter eSeverity (IEC_INT) transferred to Add2Log as
severity (BYTE).
eFacility
LLS_TFacility
Logging Facility: - area from which the error is reported
LLS_PLC_USER_LOG_SCOPE1
LLS_PLC_USER_LOG_SCOPE2
LLS_PLC_USER_LOG_SCOPE3
The Enum parameter eFacility (IEC_INT) is transferred to Add2Log as
Facility (WORD).
sLogPayLoad
STRING(80)
Logbook entry
The Ansi string from "sLogPayLoad" is transferred to Add2Log as 1-byte
string parameter. ("hs", SLOGPAYLOAD)
Przeglądanie stron 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 843 844

Komentarze do niniejszej Instrukcji

Brak uwag