Lenze PLC Designer V2.x Instrukcja Użytkownika Strona 142

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 336
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 141
PLC Designer V2.x| Lenze Application Samples
Working with the sample projects
ECS servo system - "LAS_40_INTF_Can_ECSPosShaft" sample project
142 L 1.3 EN - 07/2012
8.5.6.5 Homing mode
Button selects the homing mode.
The active standard setting in the controller is homing mode 8 (travel to positive
limit switch / digital input 2)
Button starts the homing.
Button stops homing.
Button sets the home position.
Button resets the home position.
Set reference / Pos Act = 0 unit
Dialog box shows the homing status.
Dialog box signalises whether the homing has been completed successfully.
After a successful homing, the display field is coloured in green.
Dialog box shows the current homing mode (code value).
Select mode Stop button Reset position
Start button Set position Mode status
Przeglądanie stron 141
1 2 ... 137 138 139 140 141 142 143 144 145 146 147 ... 335 336

Komentarze do niniejszej Instrukcji

Brak uwag