The L_SSC_Scaling.lib library
L_SSC_GetSpeed - conversion block (for 9400 device series)
20.4 L_SSC_GetSpeed - conversion block (for 9400 device series)
This FB converts the transmitted input speed of a 9400 controller to a speed value.
Inputs
Outputs
20.5 L_SSC_GetVersion - transfer of the version
Outputs
Identifier/data type Information/possible settings
diSpeedIn_s
DINT
Speed in [rpm] Scaling: 15000 rpm 2
26
= 67108864
scAxisData
SSC_Axis_logic
Machine parameters
Identifier/data type Information/possible settings
rSpeedOutUnits
REAL
Speed value
xError
BOOL
"Error" status signal
FALSE Conversion carried out without errors
TRUE Error during the conversion
Identifier/data type Value/meaning
dwVersion
DWORD
Output version