1.3 EN - 07/2012 L 251
PLC Designer V2.x| Lenze Application Samples
The L_S94_Drive9400.lib library
L_S94_TablePositioning - table positioning
12.4 L_S94_TablePositioning - table positioning
This FB serves to control the 9400 Highline with the "Table positioning" application.
Inputs
Outputs
Identifier/data type Information/possible settings
scDriveControl
S94_DriveControl_TablePosi
tioning
Structural data for drive control
Table positioning
scAxisData
SSC_Axis_logic
Machine parameters
For the calculation and display of the reference values on the load side (output
shaft
speed, machine speed), the reference speed (C00011), gearbox
factor, and the feed constant are required.
• In order that the machine parameters of the drive/motor are accepted, connect this
input with the output DI_AxisData of SB LS_DriveInterface.
xOptional
BOOL
Optional setting for the CAN node
TRUE: The CAN node is set to the "Optional" mode to be able to receive PDOs.
FALSE: Normal operation (transmission and reception via PDO).
byNodeNumber
BYTE
Node number
byMasterNumber
BYTE
Interface number (0...3)
Identifier/data type Information/possible settings
scDriveStatus
S94_DriveStatus_TablePositi
oning
Structural data regarding the status of the controller
Table positioning
xInternalControlActive
BOOL
TRUE: Internal control active