The L_SCS_DriveECS.lib library
L_SCS_SupplyModule - actuation of the ECS servo system power supply module
13.4.2 Structure of SCS_Status_Supply - status of the controller
Further information on the internal interfaces of the controller can be found in
the Operating instructions (BA) ECSxE_power supply module:
Section Configuration
Configure system bus | Assignment of the status words
Identifier/data type Control bits in the
controller
Bit Identifier Meaning
xBTB_ReadyForOperation
BOOL
0 STA1_BTB TRUE: Power supply module ready
xWarning
BOOL
1STA1_
WARNING
TRUE: Warning active
xMessage
BOOL
2 STA1_MESSAGE TRUE: Message active
xTrip
BOOL
3 STA1_TRIP Status message
TRUE: Error message active
xKSB_FAIL
BOOL
4 STA1_KSB_FAIL TRUE: No short-circuit braking possible,
since the DC bus is loaded externally.
xKSB_Active
BOOL
5 STA1_KSB_ACTIV
E
1 = Pulse inhibit (DCTRL-IMP) active,
inverter inhibited
xK1_Active
BOOL
6 STA1_K1_ON TRUE: No short-circuit braking possible,
since the DC bus is loaded externally.
xK2_Active
BOOL
7 STA1_K2_ON TRUE: Short-circuit braking active
xDI1
BOOL
11 STA1_DI1 1 = The actual position is in the target
window (C3034) around the target
position
(message: Target position reached)
xDI2
BOOL
12 STA1_DI2 1 = The dwell time (C3035) has expired.
Note: Bit is reset to "0" when positioning
is started.
xToggleBit
BOOL
13 STA1_TOGGLE
Toggle bit
xFreeBit14
BOOL
14 free Not assigned
xFreeBit15
BOOL
15 free Not assigned
eErrorCode
SCS_ErrorCode
Reset error