Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Instrukcja Użytkownika Strona 229

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 679
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 228
L Firmware 1.37 - 09/2006 229
9400 HighLine | Parameter setting & configuration
Basic drive functions
Brake control | Carry out brake test
9.11.6 Carry out brake test
This function can be used to check the holding torque of the brake.
O Tip!
You can carry out this test regularly to early detect defects or wear of the brake in
good time.
Requirements
To activate the brake test, the following conditions must be fulfilled:
r The test torque in C02594
is set higher than 0 Nm.
r The permissible angle of rotation in C02595
is set higher than 0° and thus standstill
monitoring is active.Standstill monitoring
(C 214)
r The brake is activated, i.e. the "brake closing time" (C02589
) and the "waiting time for
status monitoring" (C02591
) are elapsed.
r No other source for controller inhibit is active so that the controller inhibit can be
deactivated by the brake control.
Function only implemented from bundle 1.1!
Note!
Due to possible deviations in the torque generation, the test of the holding
torque cannot determine the holding torque exactly!
The generated motor torque can deviate up to ±15 % from the default value
depending on temperature.
Przeglądanie stron 228
1 2 ... 224 225 226 227 228 229 230 231 232 233 234 ... 678 679

Komentarze do niniejszej Instrukcji

Brak uwag