Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Instrukcja Użytkownika Strona 250

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 679
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 249
9400 HighLine | Parameter setting & configuration
Standard TAs
TA "Actuator – speed" | Speed setpoint conditioning
250 Firmware 1.37 - 09/2006 L
11.2.4 Speed setpoint conditioning
[11-4] Speed setpoint conditioning (schematic diagram)
The speed setpoint is defined in the Lenze setting via the analog input 1 and take place in
both directions (bipolar) and accordingly the driven machine part moves forward or
backward.
r Parameter setting: Tab Application parameter Dialog level Overview
Gain Invert setpointSelection
LS_Speed...
M
Speed
setpoint
DI2DI3DI4
OUT
IN
Ramp generator
%1
%2
%15
Fixed setpoints
Status
machine
(basic drive
functions)
Speed setpoint
AIN1
M
v
Parameters Lenze setting
Value Unit
C03002 Setpoint gain 100.00 %
Setpoint inputs of the function Signal configuration
Lenze setting Setpoint input (Multiplexer parameters)
AIn 1 Speed setpoint C03000
Przeglądanie stron 249
1 2 ... 245 246 247 248 249 250 251 252 253 254 255 ... 678 679

Komentarze do niniejszej Instrukcji

Brak uwag