L Firmware 1.37 - 09/2006 639
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C02703
C02703
C02704
C02705
C02706
C02707
Parameter | Name:
C02703 | Max. speed
Data type: INTEGER_32
Index: 21872
d
= 5570
h
Basic function "Limiter"
Setting range
(min. value | unit | max. value) Lenze setting
0.0000 Unit/s 214748.3647 3600.0000 Unit/s
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02704 | Max. speed [rpm]
Data type: INTEGER_32
Index: 21871
d
= 556F
h
Basic function "Limiter"
Display range
(min. value | unit | max. value)
0.0 rpm 214748364.7
; Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10
Parameter | Name:
C02705 | Max. acceleration
Data type: INTEGER_32
Index: 21870
d
= 556E
h
Basic function "Limiter"
Setting range
(min. value | unit | max. value) Lenze setting
0.0000 Unit/s² 214748.3647 3600.0000 Unit/s²
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02706 | Min. S-ramp time
Data type: UNSIGNED_32
Index: 21869
d
= 556D
h
Basic function "Limiter"
Setting range
(min. value | unit | max. value) Lenze setting
0 ms 10000 100 ms
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02707 | Permissible direction of rot.
Data type: UNSIGNED_32
Index: 21868
d
= 556C
h
Basic function "Limiter"
Selection list
(Lenze setting printed in bold)
0 Positive and negative
1 Positive only
2 Negative only
; Read access ; Write access CINH PLC STOP No transfer COM MOT