L Firmware 1.37 - 09/2006 583
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00416
C00416
C00420
C00421
C00422
C00427
Parameter | Name:
C00416 | Resolver error correction
Data type: UNSIGNED_32
Index: 24159
d
= 5E5F
h
Setting range (min. value | unit | max. value) Lenze setting
0 99999999 0
; Read access ; Write access ; CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00420 | Number of increments of the encoder
Data type: UNSIGNED_16
Index: 24155
d
= 5E5B
h
Setting range (min. value | unit | max. value) Lenze setting
1 16384 512
; Read access ; Write access ; CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00421 | Encoder voltage
Data type: UNSIGNED_16
Index: 24154
d
= 5E5A
h
Setting range (min. value | unit | max. value) Lenze setting
5.0 V 9.0 5.0 V
; Read access ; Write access ; CINH PLC STOP No transfer COM ; MOT Scaling factor: 10
Parameter | Name:
C00422 | Encoder type
Data type: UNSIGNED_16
Index: 24153
d
= 5E59
h
Selection list (Lenze setting printed in bold)
0 Incremental encoder (TTL signal)
1Sin/cos encoder
2 Absolute value encoder (Hiperface)
3 Absolute value encoder (EnDat)
; Read access ; Write access ; CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00427 | TTL encoder signal evaluation
Data type: UNSIGNED_16
Index: 24148
d
= 5E54
h
Selection list (Lenze setting printed in bold)
04x evaluation (A, B)
1 A:Increments B:Sign
2 Increments A:pos. B:neg.
; Read access ; Write access ; CINH PLC STOP No transfer COM ; MOT