9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Electronic gearbox" | Operating mode "Electronic gearbox"
310 Firmware 1.37 - 09/2006 L
12.2.5.2 Virtual clutch
[12-14] Function "Virtual clutch" in the signal flow (schematic diagram)
r Parameter setting: Tab Application parameter Dialog level Overview Electronic
gearbox Virtual clutch
r Configuration: Tab FB editor FB ClutchElectricalShaft
nMaster value with stretch factor
o Master value with clutch
M
v
Slave
Real master/
Virtual master
v
t
Dv
C03006 = 0

Parameters Lenze setting
Value Unit
C03673 Master value with stretch factor - Unit/t
C03021 Activate clutch Deactivated
C03665/1 Clutch in ramp 1.000 s
C03665/2 Decoupling ramp 1.000 s
C03665/3 Stop ramp 1.000 s
C03668 Jerk limitation 1.000 s
C03674 Master value with clutch - Unit/t
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
DigIn 4 Close clutch C03058/12
FALSE Clutch - positive opening operation C03058/13