L Firmware 1.37 - 09/2006 43
9400 HighLine | Parameter setting & configuration
Drive interface
Parameter setting
4.2.2 Monitoring of the device utilisation
In C00064 the device utilisation (i x t) is displayed over the last 180 seconds in [%].
r If the value displayed in C00064 exceeds the warning threshold set in C00123, the fault
message "device utilisation Ixt > C00123" is output and the fault response set in
C00604
occurs (default setting: "Warning").
r If the value displayed in C00064
exceeds 100 %, the fault message "device utilisation
Ixt > 100 %" is output and the fault response "Fault" occurs.
The fault can only be reset if the value displayed in C00064
is < 95 % again.
4.2.3 Parameter for status display
Parameters Information
C00003 Controller command status
C00007 Active application
C00150 Status word 1
C00155 Status word 2
C00183 Device state
C02530 Active function state
Highlighted in grey = display parameter