9400 HighLine | Parameter setting & configuration
TAs for positioning tasks
TA "Multi-purpose positioning" | Program flow
382 Firmware 1.37 - 09/2006 L
13.2.4.2 Action type "Homing"
In order to execute a homing process, the action type "Homing" is available for the
sequence table which activates the basic function "Homing".
[13-5] "Homing" (schematic diagram for limited traversing range)
r Parameter setting: Tab Application parameter Dialog level Overview Homing
Basic drive functions
0-100 100 200
LS_Homing
Multi-purpose positioning
DI2
Sequencer
Enable/activate
homing
Status
machine
(basic drive
functions)
M
State "homing done"
DI7
DI6
DI5
Reset
Sequencer
input 8
DI8
Note!
The "Homing" action for the sequence table does not have its own parameters.
The settings for homing are made via the parameters of the basic function
"Homing".
Parameters Lenze setting
Value Unit
C02528 Traversing range Unlimited
C02640
Ref. mode Set home pos. directly
C02642
HM position 0.0000 Unit
C02643
HM target position 0.0000 Unit
C02644
Ref. speed 1 360.0000 Unit/s
C02645
Home acceleration 1 720.0000 Unit/s
2
C02646 Ref. speed 2 180.0000 Unit/s
C02647
Home acceleration 2 360.0000 Unit/s
2
C02648 Home S-ramp time 100 ms
C02649
HM torque limit 10.00 %
C02650
Homing inhibit time 1.000 s
C02652
Home position after mains switching Delete
C02653
Max. rot. angle after mains sw. 180 °