L Firmware 1.37 - 09/2006 593
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00601
C00601
C00604
C00606
C00607
Parameter | Name:
C00601 | Resp. to comm. encoder error
Data type: UNSIGNED_32
Index: 23974
d
= 5DA6
h
Response to release of encoder monitoring
• For the use of the encoder as motor encoder: If an error occurs, the safe operation of the motor is no longer
ensured, therefore for safety reasons always the "Error" response should be set!
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
2Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00604 | Resp. to device overload
Data type: UNSIGNED_32
Index: 23971
d
= 5DA3
h
Response, if adjustable "I x t" warning threshold (C00123) is reached.
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
5 Warning
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00606 | Resp. to motor overload
Data type: UNSIGNED_32
Index: 23969
d
= 5DA1
h
Response, if adjustable "I
2
x t" warning threshold (C00127) is reached.
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
5 Warning
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00607 | Resp. to max. speed reached
Data type: UNSIGNED_32
Index: 23968
d
= 5DA0
h
Response if adjustable speed threshold (C00596) is reached.
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
2Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
; Read access ; Write access CINH PLC STOP No transfer COM MOT