L Firmware 1.37 - 09/2006 347
9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Synchronism with mark synchronisation" | "Synchronism" mode"
TP profile parameters
r Parameter setting: Tab Application parameter Dialog level Overview TP profile
parameter
r Configuration: Tab FB editor FB MarkSynchronizationShaft
TP interface
r Parameter setting: Tab Application parameter Dialog level Overview TP interface
Parameters Lenze setting
Value Unit
C03620 Positioning mode 0
C03621 Deactivation mode 0
C03623/1 Positive speed 3600.0000 Unit/t
C03623/2 Negative speed 3600.0000 Unit/t
C03626/1 Acceleration ramp 1.000 s
C03626/2 Deceleration ramp 1.000 s
C03626/3 Stop ramp 1.000 s
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
FALSE Activate master value TP correction C03058/12
Parameters Lenze setting
Value Unit
C02810/3 Signal delay TP3 0 μs
C03022 Edge evaluation of positive edge TRUE
C03024 Edge evaluation of negative edge FALSE