9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
470 Firmware 1.37 - 09/2006 L
Motor: Calculated electromotive force factor unrealistic [0x007b000b]
Motor: Calculated rotor time constant unrealistic [0x007b000c]
Motor: Calculated flux factor unrealistic [0x007b000d]
DC-bus overvoltage [0x007b000e]
DC-bus undervoltage [0x007b000f]
Overcurrent detected [0x007b0010]
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
Faulty motor parameterisation. Check motor parameters.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
Faulty motor parameterisation. Check motor parameters.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
Faulty motor parameterisation. Check motor parameters.
Response (Lenze setting printed in bold)
None System fault Fault : Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Since the braking energy is too high, the DC-bus
voltage is higher than the overvoltage threshold
which results from the mains setting in C00173
.
Use brake resistor or feedback module.
•Check setting under C00173
.
Response (Lenze setting printed in bold)
None System fault Fault : Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
DC bus voltage is lower than the undervoltage threshold
resulting from the mains setting under C00173
.
Check mains voltage.
•Check setting under C00173
.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Short circuit/earth fault in motor cable.
Excessive capacitive charging current in the motor
cable.
Check motor cable.
Use motor cable which is shorter or has a lower
capacitance.