L Firmware 1.37 - 09/2006 501
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
DFIN (MXI1): Z-/Z track error [0x00990002]
DFIN (MXI1): Enable/lamp control signal error [0x00990003]
DFIN (MXI1): Supply cannot be corrected anymore [0x00990004]
DFOUT (MXI1): Maximum frequency reached [0x00990005]
CAN module (MXI1): Bus-off [0x009d0000]
Response (Lenze setting printed in bold) Setting: C13040 (; Adjustable response)
; None System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
Digital frequency extension module in MXI1:
Interruption (open circuit) of the signal cable for track Z.
Check signal cable for track Z.
•Check encoder.
Response (Lenze setting printed in bold) Setting: C13041 (; Adjustable response)
; None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information
Cause Remedy
Digital frequency extension module in MXI1:
Interruption (open circuit) of the signal cable for the
"Enable" signal or no "Enable" signal available.
Check signal cable for "Enable" signal.
•Check encoder.
Response (Lenze setting printed in bold) Setting: C13042 (; Adjustable response)
; None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information
Cause Remedy
Digital frequency extension module in MXI1: The
encoder voltage controlled by the digital frequency input
has reached the voltage limit.
Check encoder.
Response (Lenze setting printed in bold) Setting: C13080 (; Adjustable response)
; None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information
Cause Remedy
Digital frequency extension module in MXI1: Limit
frequency at the digital frequency output reached.
The digital frequency has reached the limit value set
in C013053
.
Check set limit value.
Response (Lenze setting printed in bold) Setting: C13595 (; Adjustable response)
; None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning : Information
Cause Remedy
CANopen communication module in MXI1: "Bus-off"
state
Too many faulty telegrams received.
Cable defective (e.g. loose contact).
Two nodes with the same ID.
Remove fault (e.g. EMC).
Remove loose contact, screw down adapter.
Assign different node IDs.