Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Instrukcja Użytkownika Strona 312

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 679
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 311
9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Electronic gearbox" | Operating mode "Electronic gearbox"
312 Firmware 1.37 - 09/2006 L
12.2.5.4 Setpoint conditioning
[12-16] "Setpoint conditioning" function in the signal flow (schematic diagram)
This function is used for speed ratio between the master shaft and the machine axis.
r Parameter setting: Tab All parameters Category Electronic gearbox
ConvertElShaftMotor
r Configuration: Tab FB editor FB ConvertElShaftMotor
n Master value with trimming
o Actual value
M
v
Slave
Real master/
Virtual master
v
t
Dv
C03006 = 0
Parameters Lenze setting
Value Unit
C03715 Operating mode Unit coupling
C03717/1 Reference variable X 1.0000
C03717/2 Reference variable Y 1.0000
Przeglądanie stron 311
1 2 ... 307 308 309 310 311 312 313 314 315 316 317 ... 678 679

Komentarze do niniejszej Instrukcji

Brak uwag