Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Instrukcja Użytkownika Strona 243

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 679
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 242
L Firmware 1.37 - 09/2006 243
9400 HighLine | Parameter setting & configuration
Standard TAs
Introduction
Conveyor drive with adjustable tension
[11-2] Example: Conveyor drive with adjustable tension
r The master drive is operated speed-controlled and determines the speed of the
material path.
r The slave drive with the standard technology application "actuator – torque" ensures
that a certain minimum tensile stress is complied with between master and slave drive.
When torque-controlled, the slave drive is permanently able to follow the speed
specified by the master drive.
n Master
o Slave with technology application "actuator – torque"
p System bus (CAN)
v = speed of the material path
F = tensile stress
v
F
M
Slave
Master
ii