9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
534 Firmware 1.37 - 09/2006 L
Positive software limit switch has been overtravelled [0x00b80007]
Negative software limit switch has been overtravelled [0x00b80008]
Positive direction of rotation has been limited [0x00b80009]
Negative direction of rotation has been limited [0x00b8000a]
Speed has been limited [0x00b8000b]
Response (Lenze setting printed in bold) Setting: C02716/2 (; Adjustable response)
; None System fault ; Fault ; Trouble : Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
The positive software limit position parameterised in
C02702/2
has been overtravelled.
Position within the software limit positions.
Increase permissible traversing range (change setting
of the software limit positions).
Deactivate monitoring of the software limit positions
by the basic function "Limiter".
Response (Lenze setting printed in bold) Setting: C02716/2 (; Adjustable response)
; None System fault ; Fault ; Trouble : Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
The negative software limit position parameterised in
C02702/1
has been overtravelled.
Position within the software limit positions.
Increase permissible traversing range (change setting
of the software limit positions).
Deactivate monitoring of the software limit positions
by the basic function "Limiter".
Response (Lenze setting printed in bold) Setting: C02716/1 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
Due to the setting of C02707 it was tried to traverse in
the impermissible positive direction of rotation.
Only traverse in permissible (negative) direction of
rotation.
Change setting of the permissible direction of
rotation (C02707
).
Response (Lenze setting printed in bold) Setting: C02716/1 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
Due to the setting of C02707 it was tried to traverse in
the impermissible negative direction of rotation.
Only traverse in permissible (positive) direction of
rotation.
Change setting of the permissible direction of
rotation (C02707
).
Response (Lenze setting printed in bold) Setting: C02716/3 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
The requested profile speed is higher than the maximum
speed set in C02703
and has been limited to this speed.
Reduce speed of the traversing profile of the basic
function (manual jog, referencing or positioning).
Increase maximum speed (C02703
).
Deactivate monitoring of the limit values by the basic
function "Limiter".